American Comfort Worldwide ACW200 User Manual

Browse online or download User Manual for Split-system air conditioners American Comfort Worldwide ACW200. AP-AHS-09 (A) - Acson International [en]

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Chilled Water System

Chilled Water SystemAll Product Brochure

Page 2 - About Acson International

> > F e a t u r e s> > F e a t u r e sModular InstallationMcQuay Mini Chiller provides flexibility in adding capacity for building

Page 3 - PRODUCT LINE-UP

9Safety ProtectionThe safety protections provided for the McQuay chiller are:• High & Low Pressure Switches • Water Pressure Differential S

Page 4

> > F e a t u r e s> > F e a t u r e s TandemCompressors TandemCompressors TandemCompressorsHydroTech Mini Chiller10This new line of

Page 5

The new series of Inverter Mini Chillers are specially designed / developed to achieve better system energy saving as well as towards pe

Page 6

Advantages of inverter compressor applications are:• Less Start & Stop - Frequency regulated compressor resulting in lesser in the sens

Page 7

Chilled Water Fan Coil UnitsTo complement the new innovative HydroTech range of air cooled chillers, Acson International is offering an e

Page 8

HydroTech Chilled WaterFan Coil Units RangeWall Mounted RangeAWM 05/10/15/20/25 GWAWM 301 W✓ Slim and compact✓ Wide capacity range ✓ Wide air flow ra

Page 9 - Long Piping Application :

Ceiling Convertible RangeRCM 20/25/40/50 DWACM 15/20/25 EWACC 28/38 CW✓ Ceiling Convertible feature offers flexibility on installation • Installation

Page 10 - > > F e a t u r e s

Ceiling Concealed Range2 Pipes System:ACW 200/300/400/600/800/1000/1200 C4 Pipes System:ACW 200/300/400/600/800/1000/1200 CHADB 75/100/125/150 BW✓ Wid

Page 11 - Efficient And Performance :

Controller By adopting the HydroTech chilled water system, the comfort in residential and light commercial buildings such as offices, hospital, restau

Page 12

Central America• Barbados •Oceania• Australia • Fiji • New Caledonia • Papua New Guinea •Middle East• Jordan • Kuwait • Lebanon • Oman • Qatar • Saudi

Page 13

Alarm 1(Ch 0)Comp 1 overload01/01/0012.00amDisplay Up To 46 Types Of Chiller Fault/Alarm And 6Types Of FCU Fault/AlarmWhenever a fault occurred in

Page 14 - Modular Installation

HOLIDAY SETTINGSSet Holiday 1Holiday 1Holiday 2Holiday 3Holiday 4Holiday 5Month : 1Day : 1Duration : DisableEnergy Saving Programmable TimerThe

Page 15 - Chilled Water Fan Coil Units

> > F e a t u r e s> > F e a t u r e sMemory Backup (EEPROM), Alarm Memory for Chiller and FCUWhen there is power failure occurs during op

Page 16 - Fan Coil Units Range

HydroNIM NetworkingControl System (optional)For multiple fan coil unit installation in an office, a centralised controlled operation can

Page 17 - Ceiling Concealed Range

AC8100A and AC8000CA new developed thermostat series, AC8100A is now available to be ordered as Chilled Water Fan Coil unit controller,

Page 18 - Ducted Blower Range

AMAC20C - AMAC60C (Cooling Only, R-22)AMAC20CR - AMAC60CR (Heatpump, R-22)NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITH

Page 19 - Controller

AMAC80C - AMAC150C (Cooling Only, R-22)AMAC80C AMAC100C AMAC120C AMAC150CBtu/h 85000 95000 116000 138000W 24910 27840 34000 40450W 9050 10800 11900 13

Page 20

A4AC20C - A4AC60C (Cooling Only, R-407C)A4AC20C A4AC25C A4AC30C A4AC40C A4AC50C A4AC60CBtu/h 21000 23000 26900 38500 47500 50000W 6154 6740 7880 11280

Page 21 - Holiday Setting

A4AC80C - A4AC150C (Cooling Only, R-407C)l/s/ m3 /hrA4AC80C A4AC100C A4AC120C A4AC150CBtu/h 80000 90000 115000 137000W 23450 26380 33700 40150W 9600 1

Page 22

A5AC20CR - A5AC55CR (Heatpump, R-410A)A5ACV30CR - A5ACV135CR (Inverter Heatpump, R-410A)NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MAN

Page 23 - Control System (optional)

Pg.S1 - Pg.S4 Pg.S5 Pg.S11 Pg.S6 Pg.S7 Pg.S9Pg.S8Pg.S8Pg.S5Pg.5 - Pg.9Pg.S5Pg.5 - Pg.9 Pg.10 Pg.14 Pg.14 Pg.14 Pg.15Pg.S10Pg.16Pg.S11Pg.16Pg.15Pg.S12P

Page 24 - AC8100A and AC8000C

ACK20AW - ACK50AW (Ceilling Cassette A Series)NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNIT

Page 25 - Mini Chiller Specifications

ACK10CW - ACK20CW (Ceilling Cassette C Series)NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNIT

Page 26

RCM07CBW - RCM15CBW (Ceilling Exposed)NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BE

Page 27 - A4AC60CR (Heatpump, R-407C)

ACC30CW - ACC60CW (Ceiling Concealed)HIGHMEDIUMLOWHIGHHEIGHTWIDTHDEPTHHEAD LOSS (COOLING)HEAD LOSS (HEATING) : 50°CCONNECTION50HZ60HZEXTERNAL STATIC (

Page 28

ACW200H - ACW1200H (Ceilling Concealed)ACW200H ACW300H ACW400H ACW600H ACW800H ACW1000H ACW1200HBtu/h 7268 10578 14536 20405 25864 29242 35418W 2130 3

Page 29

AWM07GW - AWM25GW (Wall Mount)Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TEST

Page 30

ACM15EW - ACM25EW (Ceiling Convertible)Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE B

Page 31

AP - AHS - 09Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.For th

Page 32

Pg.S7 Pg.S9Pg.S8Pg.S8Pg.14 Pg.15Pg.S10Pg.16Pg.S11Pg.16Pg.15Pg.S12Pg.15 Pg.15PRODUCT LINE-UPChiller Network BUS Fan Coil Network BUSHydrointel Contro

Page 33

> > I n t r o d u c t i o n> > I n t r o d u c t i o nChilled Water SystemChilled Water SystemAcson International is committed to off

Page 34

> > F e a t u r e s> > F e a t u r e s chilled waterseries of products 3. Long Piping ApplicationsThe HydroTech series avoid

Page 35

Air Cooled Mini Chiller Series Acson International offering you the range of air cooled chiller that is suitable for many applications f

Page 36

> > P r o d u c t R a n g e> > P r o d u c t R a n g eModel :AMAC 80/100/120/150 C/CRA4AC 80/100/120/150 C/CRA5ACV 100/135/210 CR Capa

Page 37

Multistage End Suction Water PumpImpeller and all movable parts in contact with the water are made of stainless steels.Diaphragm Expansion

Comments to this Manuals